Redirigiendo al acceso original de articulo en 21 segundos...
Inicio  /  Applied Sciences  /  Vol: 11 Par: 7 (2021)  /  Artículo
ARTÍCULO
TITULO

Numerical Evaluation of Spinal Stability after Posterior Spinal Fusion with Various Fixation Segments and Screw Types in Patients with Osteoporotic Thoracolumbar Burst Fracture Using Finite Element Analysis

Cheol-Jeong Kim    
Seung Min Son    
Sung Hoon Choi    
Tae Sik Goh    
Jung Sub Lee and Chi-Seung Lee    

Resumen

The aim of this study was to analyze the spinal stability and safety after posterior spinal fusion with various fixation segments and screw types in patients with an osteoporotic thoracolumbar burst fracture based on finite element analysis (FEA). To realize various osteoporotic vertebral fracture conditions on T12, seven cases of Young?s modulus, namely 0%, 1%, 5%, 10%, 25%, 50%, and 100% of the Young?s modulus, for vertebral bones under intact conditions were considered. Four types of fixation for thoracolumbar fracture on T12 (fixed with T11-L1, T10-T11-L1, T11-L1-L2, and T10-T11-L1-L2) were applied to the thoracolumbar fusion model. The following screw types were considered: pedicle screw (PS) and cortical screw (CS). Using FEA, four motions were performed on the fixed spine, and the stress applied to the screw, peri-implant bone (PIB), and intervertebral disc (IVD) and the range of motion (ROM) were calculated. The lowest ROM calculated corresponded to the T10-T11-L1-L2 model, while the closest to the intact situation was achieved in the T11-L1-L2 fixation model using PS. The lowest stress in the screw and PB was detected in the T10-T11-L1-L2 fixation model.

 Artículos similares

       
 
Adnan Mukhtar, Sajid Latif, Ziba Barati and Joachim Müller    
Cassava production generates significant amounts of by-products such as leaves and tuber peel. Instead of considering them as waste, valorization aims to find sustainable ways to utilize them. However, the presence of cyanide and insoluble fibers poses a... ver más
Revista: Applied Sciences

 
Soo-Min Kim, Dae W. Kim and Moon K. Kwak    
The membrane-type air spring can be used to suppress lateral vibration of a vibration isolation table. However, compared to voice coil actuators, pneumatic actuators are difficult to use for precise vibration control, because servo valves have nonlinear ... ver más
Revista: Applied Sciences

 
Ke Chen, Bo Xiao, Chunyang Wang, Xuelian Liu, Shuning Liang and Xu Zhang    
In today?s automation control systems, the PID controller, as a core technology, is widely used to maintain the system output near the set value. However, in some complex control environments, such as the application of ball screw-driven rotating motors,... ver más
Revista: Applied Sciences

 
Chih-Chang Chang, Chao-Hung Kuo, Hsuan-Kan Chang, Tsung-Hsi Tu, Li-Yu Fay, Jau-Ching Wu, Henrich Cheng and Wen-Cheng Huang    
Percutaneous pedicle screw instrumentation is the keystone of minimally invasive spine surgery. Percutaneous screw placement demands experience and relies greatly on intra-operative image guidance. This study aims to validate the feasibility and accuracy... ver más
Revista: Applied Sciences

 
Giuseppe Pantaleo, Alfonso Acerra, Francesco Giordano, Francesco D?Ambrosio, Michele Langone and Mario Caggiano    
The aim of this retrospective single-cohort study was to evaluate the clinical outcome of four-to-five implants immediately restored with metal-resin screw-retained cross-arch fixed prostheses in edentulous jaws 10 years after loading. One-hundred-and-fo... ver más
Revista: Applied Sciences