This paper presents the behavior of concrete-filled steel tube (CFST) columns infilled with fiber-reinforced self-consolidating ultrahigh strength concrete (UHSC) subjected to axial concentric monotonic loading to failure. UHSC is expected to improve ease of fabrication, strength, and ductility of CFST columns. Seventeen columns having varying geometric properties such as tube wall thickness, cross-sectional shape (circular, rectangular, and square), and slenderness were constructed and tested by applying load through both steel tube and concrete core. Circular columns were further distinguished by the presence or absence of main and hoop steel reinforcing bars in the core concrete. Axial load-displacement response, axial/transverse strain development, and failure modes were recorded during the loading history to analyze the performance. Experimental confined concrete strength and axial strength of UHSC-filled CFST columns were compared with those obtained from three suggested analytical models and three code-based design procedures including Eurocode 4, Canadian CAN/CSA S16, and American AISC. Analytical models were found to over-predict the confined concrete strength and the axial strength of CFST columns. Canadian and American codes were found to be most applicable for predicting axial strength of UHSC-filled CFST columns while remaining conservative.

 Artículos similares

       
 
Jiuzhi Fu, Yang Zhang and Yanyue Qin    
In this investigation, the effects of different fabrics with 0.20% carbon fiber textile (CFT), 0.21% glass fiber textile (GFT), and 0.25% basalt fiber textile (BFT) on the properties of TR-UHPC were investigated by axial tensile tests. A bending test of ... ver más
Revista: Applied Sciences

 
Subin Kim, Heejin Hwang, Keunyeong Oh and Jiuk Shin    
The seismically deficient column details in existing reinforced concrete buildings affect the overall behavior of the building depending on the failure type of the column. The purpose of this study is to develop and validate a machine-learning-based pred... ver más
Revista: Applied Sciences

 
Irem Zeynep Yildirim, Berk Turkel and Erol Guler    
Mechanically stabilized earth (MSE) walls perform well under earthquake loads, and hence they are preferred in earthquake-prone regions. The multifaceted load transfer between the components of the MSE wall under seismic loads can be captured using numer... ver más
Revista: Buildings

 
Chenhua Jin, Yanli Su, Zuanfeng Pan and Shaoping Meng    
Experimental observations on three reinforced concrete shear walls with small shear span-to-depth ratio (SDR) under combined high vertical axial load and horizontal cyclic loads are presented. The influence of high axial load ratio (ALR) on the failure m... ver más
Revista: Buildings

 
Shovona Khusru, David P. Thambiratnam, Mohamed Elchalakani and Sabrina Fawzia    
Rubberised concrete has emerged as a material of interest to the research community with the mission of creating sustainable structural members and decreasing the burden of waste tyre rubber. The potential benefits of replacing natural aggregates with ru... ver más