Resumen
Based on an actual excavation of a metro station in Tianjin, China, a fluid?solid coupling numerical model was developed to study the characteristics of groundwater flow and strata movement induced by dewatering and excavation considering the barrier effect of pre-existing adjacent underground structures. Two parameters were selected for the model: the distance between the excavation and the existing underground structure (D), and the buried depth of the adjacent structure (H). By comparing the distribution of groundwater drawdown and deformation modes of the retaining structure and the strata under different working conditions, the influence mechanism of adjacent structures on the movement of groundwater and strata was revealed. The results show that the pile foundations have different effects on the groundwater flow and excavation deformation. Generally, the maximum groundwater drawdown could be enlarged by considering the adjacent underground structure, while the retaining structure deflection would be reduced and the ground settlement could be either enlarged or reduced. Additionally, as D decreases and H increases, a much greater groundwater drawdown and a much smaller retaining structure deflection would appear, which together affect the ground behavior. On the one hand, greater groundwater drawdown would lead to greater ground settlement by soil consolidation, while on the other hand, a smaller retaining structure deflection would lead to smaller ground settlement. Thus, a complex development of ground settlement would appear, and a specific analysis should be performed to assess this in practice, based on a specific H and D.