Redirigiendo al acceso original de articulo en 20 segundos...
Inicio  /  Applied Sciences  /  Vol: 10 Par: 3 (2020)  /  Artículo
ARTÍCULO
TITULO

Performance Analysis of the Supercritical Carbon Dioxide Re-compression Brayton Cycle

Mohammad Saad Salim    
Muhammad Saeed and Man-Hoe Kim    

Resumen

This paper presents performance analysis results on supercritical carbon dioxide (sCO2" role="presentation">??????2sCO2 s C O 2 ) re-compression Brayton cycle. Monthly exergy destruction analysis was conducted to find the effects of different ambient and water temperatures on the performance of the system. The results reveal that the gas cooler is the major source of exergy destruction in the system. The total exergy destruction has the lowest value of 390.1 kW" role="presentation">390.1 kW390.1 kW 390.1   kW when the compressor inlet temperature is near the critical point (at 35" role="presentation">3535 35 °C) and the compressor outlet pressure is comparatively low (24 MPa" role="presentation">24 MPa24 MPa 24   MPa ). The optimum mass fraction (x) and efficiency of the cycle increase with turbine inlet temperature. The highest efficiency of 49% is obtained at the mass fraction of x = 0.74 and turbine inlet temperature of 700 °C. For predicting the cost of the system, the total heat transfer area coefficient (UATotal" role="presentation">??????????????UATotal U A T o t a l ) and size parameter (SP) are used. The UATotal" role="presentation">??????????????UATotal U A T o t a l value has the maximum for the split mass fraction of 0.74 corresponding to the maximum value of thermal efficiency. The SP value for the turbine is 0.212 dm at the turbine inlet temperature of 700 °C and it increases with increasing turbine inlet temperature. However the SP values of the main compressor and re-compressor increase with increasing compressor inlet temperature.

 Artículos similares

       
 
Bahareh Kalantar, Husam A. H. Al-Najjar, Biswajeet Pradhan, Vahideh Saeidi, Alfian Abdul Halin, Naonori Ueda and Seyed Amir Naghibi    
Assessment of the most appropriate groundwater conditioning factors (GCFs) is essential when performing analyses for groundwater potential mapping. For this reason, in this work, we look at three statistical factor analysis methods?Variance Inflation Fac... ver más
Revista: Water

 
Young Hwan Choi and Joong Hoon Kim    
This study compares the performance of self-adaptive optimization approaches in efficient water distribution systems (WDS) design and presents a guide for the selection of the appropriate method employing optimization utilizing the characteristic of each... ver más
Revista: Water

 
Alessio Siciliano, Giulia Maria Curcio and Carlo Limonti    
The pollution of water by nitrates represents an important environmental and health issue. The development of sustainable technologies that are able to efficiently remove this contaminant is a key challenge in the field of wastewater treatment. Chemical ... ver más
Revista: Water

 
Márta Simon, Alvise Vianello and Jes Vollertsen    
In this paper, we evaluate the performance of a disc filter that retains microplastic (MP) particles from treated wastewater. A focal plane array-based Fourier transform infrared imaging technique enabled MP quantification and an in-house-built software ... ver más
Revista: Water

 
Rick Jaeger, Carolyn Jacobs, Katharina Tondera and Neil Tindale    
This study investigated different approaches to optimize flows in misaligned culverts. Structures aligned with the natural stream are always preferred, as misalignments cause a change of direction at the culvert inlet associated with lower performance an... ver más
Revista: Water