Redirigiendo al acceso original de articulo en 19 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 5 (2023)  /  Artículo
ARTÍCULO
TITULO

Application and Analysis of a Heat Pump System for Building Heating and Cooling Using Extracting Heat Energy from Untreated Sewage

Zhaoyi Zhuang    
Jin Zhao    
Fengfeng Mi    
Teng Zhang    
Yuguo Hao and Shangyue Li    

Resumen

Heat pump technology can extract low-level heat energy from urban sewage to heat or cool buildings, which can alleviate the two major problems of energy shortage and environmental pollution to a certain extent. This paper introduces the principle of wastewater source heat pump technology and summarizes the current common system forms and their key core technologies. The proposed special heat transfer technology for sewage can effectively solve the problem of blockage and corrosion in the process of sewage heat transfer. Taking the system of an office building in Qingdao as an example, the system design parameter is introduced in detail. The operation monitoring of the heating and air conditioning seasons of this project was completed through a data collection system, and various performance parameters of the system were studied and analyzed. The data was obtained using measured data from one year of system operation. The testing results show that the sewage temperature of the heat pump system in winter is approx. 13.5 °C, the hot water supply temperature is approx. 50 °C, the average COP of the unit is 3.95, and the average COP of the system is 2.96. The calculation results show that the heating energy consumption of the heat pump unit is only 50.81% of that of a traditional heating mode coal-fired boiler and 57.57% of that of an air source heat pump system. In summer, the sewage temperature is approx. 22 °C, the cold-water supply temperature is approx. 5.5 °C, the average COP of the unit is 4.45, and the average COP of the system is 3.25. The cooling energy consumption of the heat pump system is 79.39% of the energy consumption of the traditional chiller and 61.56% of the cooling energy consumption of the air source heat pump system. This shows that the sewage source heat pump system has a remarkable energy-saving effect.

 Artículos similares

       
 
Rehab O. Abdel Rahman, Ahmed M. El-Kamash and Yung-Tse Hung    
Permeable concrete is a class of materials that has long been tested and implemented to control water pollution. Its application in low-impact development practices has proved its efficiency in mitigating some of the impacts of urbanization on the enviro... ver más
Revista: Water

 
Siliang Yang, Francesco Fiorito, Alistair Sproul and Deo Prasad    
Energy used in buildings is mainly attributed to provide the desired thermal comfort, which could result in an increase in carbon emission and, in turn, lead to further environmental degradation. A Building-Integrated Photovoltaic Double-Skin Façade (BIP... ver más
Revista: Buildings

 
William Villegas-Ch, Joselin García-Ortiz and Angel Jaramillo-Alcazar    
This paper investigated the importance of explainability in artificial intelligence models and its application in the context of prediction in Formula (1). A step-by-step analysis was carried out, including collecting and preparing data from previous rac... ver más

 
Guangteng Bai, Juyang Fu, Qian Zhou and Xiangliang Pan    
Tire wear particles (TWPs), as a type of thermosetting microplastic (MP), accumulate in aquatic environments due to their wide application in road traffic globally. The increase in temperature because of friction heat may cause aging of tire materials, i... ver más
Revista: Water

 
Chao Fan, Xiang Que, Zhe Wang and Xiaogang Ma    
The urban heat island (UHI) effect is an important topic for many cities across the globe. Previous studies, however, have mostly focused on UHI changes along either the spatial or temporal dimension. A simultaneous evaluation of the spatial and temporal... ver más