Performance Analysis of Hybrid Desiccant Cooling System with Enhanced Dehumidification Capability Using TRNSYS

Ji Hyeok Kim and Joon Ahn    

Resumen

In a field test of a hybrid desiccant cooling system (HDCS) linked to a gas engine cogeneration system (the latter system is hereafter referred to as the combined heat and power (CHP) system), in the cooling operation mode, the exhaust heat remained and the latent heat removal was insufficient. In this study, the performance of an HDCS was simulated at a humidity ratio of 10 g/kg in conditioned spaces and for an increasing dehumidification capacity of the desiccant rotor. Simulation models of the HDCS linked to the CHP system were based on a transient system simulation tool (TRNSYS). Furthermore, TRNBuild (the TRNSYS Building Model) was used to simulate the three-dimensional structure of cooling spaces and solar lighting conditions. According to the simulation results, when the desiccant capacity increased, the thermal comfort conditions in all three conditioned spaces were sufficiently good. The higher the ambient temperature, the higher the evaporative cooling performance was. The variation in the regeneration heat with the outdoor conditions was the most dominant factor that determined the coefficient of performance (COP). Therefore, the COP was higher under high temperature and dry conditions, resulting in less regeneration heat being required. According to the prediction results, when the dehumidification capacity is sufficiently increased for using more exhaust heat, the overall efficiency of the CHP can be increased while ensuring suitable thermal comfort conditions in the cooling space.

 Artículos similares

       
 
Bahareh Kalantar, Husam A. H. Al-Najjar, Biswajeet Pradhan, Vahideh Saeidi, Alfian Abdul Halin, Naonori Ueda and Seyed Amir Naghibi    
Assessment of the most appropriate groundwater conditioning factors (GCFs) is essential when performing analyses for groundwater potential mapping. For this reason, in this work, we look at three statistical factor analysis methods?Variance Inflation Fac... ver más
Revista: Water

 
Young Hwan Choi and Joong Hoon Kim    
This study compares the performance of self-adaptive optimization approaches in efficient water distribution systems (WDS) design and presents a guide for the selection of the appropriate method employing optimization utilizing the characteristic of each... ver más
Revista: Water

 
Alessio Siciliano, Giulia Maria Curcio and Carlo Limonti    
The pollution of water by nitrates represents an important environmental and health issue. The development of sustainable technologies that are able to efficiently remove this contaminant is a key challenge in the field of wastewater treatment. Chemical ... ver más
Revista: Water

 
Márta Simon, Alvise Vianello and Jes Vollertsen    
In this paper, we evaluate the performance of a disc filter that retains microplastic (MP) particles from treated wastewater. A focal plane array-based Fourier transform infrared imaging technique enabled MP quantification and an in-house-built software ... ver más
Revista: Water

 
Rick Jaeger, Carolyn Jacobs, Katharina Tondera and Neil Tindale    
This study investigated different approaches to optimize flows in misaligned culverts. Structures aligned with the natural stream are always preferred, as misalignments cause a change of direction at the culvert inlet associated with lower performance an... ver más
Revista: Water