Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Applied Sciences  /  Vol: 10 Par: 24 (2020)  /  Artículo
ARTÍCULO
TITULO

Comparison between Occlusal Errors of Single Posterior Crowns Adjusted Using Patient Specific Motion or Conventional Methods

Ye-Chan Lee    
Chunui Lee    
June-Sung Shim    
Ji-Man Park    
Yooseok Shin    
Jong-Eun Kim and Keun-Woo Lee    

Resumen

Recently, digital technology has been used in dentistry to enhance accuracy and to reduce operative time. Due to advances in digital technology, the integration of individual mandibular motion into the mapping of the occlusal surface is being attempted. The Patient Specific Motion (PSM) is one such method. However, it is not clear whether the occlusal design that is adjusted using PSM could clinically show reduced occlusal error compared to conventional methods based on static occlusion. In this clinical comparative study including fifteen patients with a single posterior zirconia crown treatment, the occlusal surface after a clinical adjustment was compared to no adjustment (NA; design based on static occlusion), PSM (adjusted using PSM), and adjustment using a semi-adjustable articulator (SA) for the assessment of occlusal error. The root mean square (RMS; µm), average deviation value (±AVG; µm), and proportion inside the tolerance (in Tol; %) were calculated using the entire, subdivided occlusal surface and the out of tolerance area. Using a one-way ANOVA, the RMS and +AVG from the out of tolerance area showed a statistical difference between PSM (202.3 ± 39.8 for RMS, 173.1 ± 31.3 for +AVG) and NA (257.0 ± 73.9 for RMS, 210.9 ± 48.6 for +AVG). For the entire and subdivided occlusal surfaces, there were no significant differences. In the color-coded map analysis, PSM demonstrated a reduced occlusal error compared to NA. In conclusion, adjustment occlusal design using PSM is a simple and effective method for reducing occlusal errors that are difficult to identify in a current computer-aided design (CAD) workflow with static occlusion.

 Artículos similares

       
 
Fang Gui, Jiaoyun Yang, Yiming Tang, Hongtu Chen and Ning An    
The life stories of older adults encapsulate an array of personal experiences that reflect their care needs. However, due to inherent fuzzy features, fragmented natures, repetition, and redundancies, the practical application of the life story approach p... ver más
Revista: Applied Sciences

 
Srdan ?ivkovic, Nenad Stojkovic, Dragana Turnic, Marko Milo?evic and Marija Spasojevic ?urdilovic    
Welded structural hollow sections are becoming increasingly used in contemporary civil engineering buildings. More specific design techniques are needed for connections in steel structures with welded structural hollow sections than for traditional conne... ver más
Revista: Applied Sciences

 
Nader Vahdati, Aamna Alteneiji, Fook Fah Yap and Oleg Shiryayev    
Engine mounts serve three primary purposes: (1) to support the weight of the engine, (2) to lessen the transmitted engine disturbance forces to the vehicle structure/chassis or airplane fuselage, and (3) to limit the engine motion brought on by shock exc... ver más
Revista: Applied Sciences

 
Florin Leon, Marius Gavrilescu, Sabina-Adriana Floria and Alina Adriana Minea    
This paper proposes a classification methodology aimed at identifying correlations between job ad requirements and transversal skill sets, with a focus on predicting the necessary skills for individual job descriptions using a deep learning model. The ap... ver más
Revista: Information

 
Hanqiao Han, Yun Long and Jinqing Zhong    
When we tested the water jet propulsion pump, we found that there were significant vibrations in the pump, especially at small flow points that deviated from the design conditions. The water jet propulsion pump is a mixed-flow pump with guide vane, which... ver más